Report Debugging

Anuj BHEL Hardwar India wrote in message ...

>Hello,
>
>I have a report frame in Ingres II on SUN Solaris. The screen accepts one
>character parameter which ends with a '%' sign, i.e., indicating a like
>predicate. When the report frame is run, it gives the following error:
>
> E_RW1001 Bad parameter specified at or near '%)'
> Correct usage of REPORT command is :
>  .
>  .
>  .
> Processing stops.
>
>But when I run the same report on the OS prompt by
>   report dbname report-name
> it asks for the parameter and I give the same value ending with a '%'
> and the report runs fine.
>
>What is the problem ?
>
>Anuj.


Hello,

set II_UTEXE_DEBUG to 'true' prior to starting your application. This will
show you all generated commands and will probably help diagnosing the
problem.

Kind regards

Sarkaut Mohn
Technical Support
Computer Associates, Germany
Ingres Q & A
Back to William's Home Page

© William Yuan 2000

Email William